-
OlachiWe purchased the modular single-channel-ROW product from Liruisi Electronics. This product takes into account standardized design, energy saving and expansion compatibility, and uses standardized power supply, cooling and cabinet units, allowing us to plan, expand and manage more conveniently. Critical facilities in data centers.
-
CharlesLiruisi Electronics has shown us their commitment and focus on their customers. They patiently listened to our needs and provided customized solutions based on our requirements. The team was professional and it was a pleasure working with them.
-
LeahLiruisi Electronics' products are of excellent quality and we are very satisfied with our use of their equipment. Their products are well designed and have excellent reliability and stability. Whether it's the sales staff or the technical support team, they always respond quickly and resolve our issues.
LIRUISI communication battery 12V 17Ah valve regulated sealed lead-acid battery LC12-17

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xUsage | UPS | Application | UPS |
---|---|---|---|
Nominal Capacity | 17ah | Battery Type | Gel And Deep Cycle/AGM |
Type | Deep Cycle | Electrolyte | Sulfuric Acid Thixotropic |
Product introduction:
Communication battery LC series 12V valve-regulated sealed lead-acid battery has good performance, safety and stability. It is well evaluated by the majority of users in the battery.
LC series 12V valve regulated sealed lead-acid battery series product specifications:
Model | voltage | Capacity 20 hour rate | Dimensions (mm) | Total weight Approx. (kg) | |||
Length (L) | Width (W) | High (H) | Total height (TH) | ||||
LC12-17 | 12 | 17 | 181 | 76 | 167 | 167 | 6.5 |
Installation, use and maintenance
Connection of the battery:
1. Batteries or battery packs with the same actual capacity can be used in series
2. Cells or battery packs with the same actual voltage can be used in parallel
3. The connection part should be tight to prevent sparks; If the contact is poor, the contact surface can be cleaned with soda
4. The positive and negative poles shall not be reversed or short-circuited
5. The batteries of the battery pack should be spaced more than 10mm apart to facilitate heat dissipation
Battery charging:
1. Float charge (limit voltage, control current) use: charging voltage 2.275-2.30V/single cell, temperature compensation, temperature compensation coefficient per unit is 3mv (based on 20)
2. When trickle is used, the battery float charge current is high speed to less than 2Ma/Ah
3. Cycle use (full and stop, discharge and charge): charging voltage 2.35-2.45V/single cell
4. The maximum current shall not be greater than 25% of the nominal capacity
Note: The battery should not be used in a closed or high temperature environment and should be kept away from fire
Storage and installation:
1. The battery that is not in use should be removed from the connecting cable, covered with the pole sheath and wiped clean
2. Maintain and charge the battery every three months, the charging method is the current limiting and constant voltage method, the initial charging current is 0.1CA, and the charging voltage is 2.4V/single cell
3. The battery should be stored in a dry and ventilated place, away from direct sunlight and away from heat sources
4. When handling the battery, the force should be evenly applied, and the force should be the shell part of the battery to avoid operating the pole column
5. Insulating tools should be used during installation to prevent electric shock
Notes:
1. The battery is shipped with liquid and must not attempt to disassemble the battery to avoid danger. If the battery case is accidentally damaged and contact sulfuric acid, please rinse with plenty of water, and seek medical attention immediately if necessary
2. Do not mix new and old batteries
3. Do not use batteries in sealed containers
4. The battery should have a complete resume, including factory date, installation date, operation record, etc
5. Check regularly (once a year) whether the connecting wire is loose, and if there is looseness, it should be tightened
6. Regularly (once every three months) wipe the battery with a soft fabric to keep the battery clean
7. Do not use organic solvents to clean the battery
8. Pay attention to the battery interval to prevent salt bridges