OlachiWe purchased the modular single-channel-ROW product from Liruisi Electronics. This product takes into account standardized design, energy saving and expansion compatibility, and uses standardized power supply, cooling and cabinet units, allowing us to plan, expand and manage more conveniently. Critical facilities in data centers.
-
CharlesLiruisi Electronics has shown us their commitment and focus on their customers. They patiently listened to our needs and provided customized solutions based on our requirements. The team was professional and it was a pleasure working with them.
-
LeahLiruisi Electronics' products are of excellent quality and we are very satisfied with our use of their equipment. Their products are well designed and have excellent reliability and stability. Whether it's the sales staff or the technical support team, they always respond quickly and resolve our issues.
Single Row Module Micro Data Center Energy Saving Capacity Expansion Compatibility
Place of Origin | China |
---|---|
Brand Name | lpsrits |
Minimum Order Quantity | 1 set of |
Price | bargaining |
Packaging Details | The single row scheme of the micro module data center fully considers the standardized design, energy conservation and capacity expansion compatibility, and uses standardized power, refrigeration and cabinet units to help IT experts seamlessly plan, expand |
Delivery Time | 8 working days |
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xCabenit Quanity | LESS THAN 20 | ITcabenit Quanity | LESS THAN 20 |
---|---|---|---|
POWER DENITISY -kW/CAbinet | Less Than15kW/CABINET | Redundancy Style | N/N+1/2N |
UPSCAPACITY -kVA | MAX90kVA | UPS | Rack-mounted Modular |
High Light | Module Micro Data Center,ODM Micro Data Center |
Single Row Scheme Of Micro Module Data Center Energy Saving And Capacity Expansion Compatibility
Advantages and characteristics
VMDC-06-RRS
cabenit: 1*Integrated cabinet+ 1*IT cabenit
UPS: 6kVA rack-mounted
cooling: 5.6kW InRow air-conditioner
Redundancy:N
VMDC-10-RRS
cabenit 1*Integrated cabinet+ 2*ITcabenit
UPS: 10+10(kVA)rack-mounted
cooling: 7.6+7.6kWInRow air-conditioner
Redundancy: N+1
VMDC-20-RRS
cabenit: 1*Integrated cabinet+ 4*ITcabenit
UPS: 20+20(kVA)rack-mounted
cooling: 17.6+17.6kW InRow air-conditioner
Redundancy: N+1
VMDC-30-RRS
cabenit: 1*Integrated cabinet+ 6*ITcabenit
UPS: 30+30(kVA)rack-mounted
cooling: 25.1+25.1kW InRow air-conditione
Redundancy: N+1
VMDC-40-RRS
cabenit: 1*Integrated cabinet+ 9*ITcabenit
UPS: 40+10(kVA)modular
cooling: 21.2*(2+1)kW
Redundancy: N+1
Technical
monitoring system
model | VMDC-06-RRS | VMDC-10-RRS | VMDC-20-RRS | VMDC-30-RRS | VMDC-40-RRS | ODM |
cabenit quanity | 2 | 3 | 5 | 7 | 10 | LESS THAN 20 |
ITcabenit quanity | 2 | 3 | 4 | 6 | 9 | LESS THAN 20 |
POWER DENITISY -kW/CAbinet | 2 | 2 | 4 | 4 | 4 | less than15kW/CABINET |
Redundancy style | N | N+1 | N+1 | N+1 | N+1 | N/N+1/2N |
depth -mm | 1400 | 1400 | 1400 | 1400 | 1400 | customization |
length -mm | 1500 | 2400 | 3600 | 5700 | 6900 | customization |
height -mm | 2000 | 2000 | 2000 | 2000 | 2000 | less than 2500 |
POWER SYSTEM | ||||||
UPSCAPACITY -kVA | 6 | 10+10 | 20+20 | 30+30 | 40+10 | MAX90kVA |
UPS | rack-mounted | rack-mounted | rack-mounted | rack-mounted | modular | rack-mountedmodular |
)battery configuration(1 h) | 12V/40Ah 16Pcs | 12V/65Ah 16Pcs | 12V/65Ah 40Pcs | 12V/100Ah 40Pcs | 12V/150Ah 40Pcs | customization |
PDU | 32A basic 16 port | 32A basic 16 port | 32A basic 16 port | 32A basic 16 port | 32A basic 16 port | customization |
Total input power specification |
63A/1P/220V /50Hz/60Hz |
63A/3P/380V /50Hz/60Hz |
80A/3P/380V /50Hz/60Hz |
125A/3P/380V /50Hz/60Hz |
160A/3P/380V /50Hz/60Hz |
customization |
cooling system | ||||||
cooling style | Air cooling | Air cooling | Air cooling | Air cooling | Air cooling | Air cooling, water cooling and chilled water |
air-conditioner configuration-kW | 5.6 | 7.6+7.6 | 17.6+17.6 | 25.1+25.1 | 21.2*(2+1) | Per Situation |
air-conditioner sytle | InRow | InRow | InRow | InRow | InRow | Row / rack / top mounted |
Emergency ventilation | Automatic door opening | Automatic door opening | Automatic door opening | Automatic door opening | Automatic door opening | Automatic door opening |
monitoring sysem | ||||||
monitoring | Touch screen | Touch screen | Touch screen | Touch screen | Touch screen | Optional video, access control, audible and visual / SMS alarm, centralized monitoring, etc |
Temperature and humidity | Temperature and humidity | Temperature and humidity | Temperature and humidity | Temperature and humidity | ||
UPS management | UPS management | UPS management | UPS management | UPS management | ||
air-conditioner management | air-conditioner management | air-conditioner management | air-conditioner management | air-conditioner management | ||
smoke detection | smoke detection | smoke detection | smoke detection | smoke detection | ||
water leakage | water leakage | water leakage | water leakage | water leakage漏水 | ||
Door opening status | Door opening status | Door opening status | Door opening status | Door opening status |
The single row scheme of micro module data center fully considers the standardized design, energy saving and capacity expansion compatibility, and adopts standardized power supply, refrigeration and cabinet units to help it experts seamlessly plan, expand and manage these key infrastructure of data center for the future.